Information and Instructions Siro Air Sauna Chimney

Air Cooling – an innovation you won't find in other sauna chimneys. Thanks to the air cooling, the Siro Air sauna stove chimney is the safest option for a sauna chimney. Its narrow outer diameter makes it ideal for a small sauna stove.

 

The sauna stove chimney is also very easy and quick to install thanks to its own installation kit.

"T800" Class Sauna Chimney

 

The demanding conditions of the sauna room have been considered in the design of the Siro Air sauna stove chimney. For example, sauna stoves do not allow the same combustion control as more advanced fireplaces. Additionally, the combustion technology in sauna stoves is compact, resulting in higher flue gas temperatures than in regular fireplaces.

 

In the Siro Air Sauna, air continuously flushes the structure, preventing it from overheating. The hotter the air, the faster it moves, ensuring the structure does not overheat even during heavy use.

 

Applicability:

  • Tested for vertical installation and at 30° and 90° angles
  • Uniquely tested at 855 °C with a 6-hour operational temperature test and a 30-minute 1000 °C soot fire test, which determined a 26 mm clearance to combustible material.
  • Tested for encased structures

 The product system includes an underlay and vapor barrier seal made from EPDM rubber compound, as well as roof sealing, when ordered. The chimney connections are tested for placement within building insulation. The chimney allows for installations in encased structures and wall penetrations.

 

TECHNICAL SPECIFICATIONS

Usage

Sauna stoves

Suitable fuels

Wood, pellets, gas, oil

Thermal insulation value

1,73 m2K/W – at reference temperature of 200°C.

Fire sfaety distance (mm)

26 

Structure from inside out

Inner pipe, ceramic insulation, aluminium, air gap, aluminium, mineral wool, steel jacket

Insulation type

alkaline earth silicate insulation + Paroc Chimney Section mineral wool

Flue pipe sizes (mm)

114 (converted with an adapter to fit the fireplace outlet)

Outer diameters (mm)

238

Temperature class

T600 

Wall penetrations

No

For enclosed structures

Yes

Lateral shifts

No

Product standard

EN 1856-1:2009

Type code

T600-N1-D/W-Vm-L50060-G26 / T600-N1-D/W-Vm-L20070-G26