TECHNICAL SPECIFICATIONS
|
Usage |
Fireplaces, stoves, masonry heaters, baking ovens, heating boilers, ventilation, outdoor kitchen grill, sauna stoves, charcoal grills, kitchen stoves
|
Application |
Detached houses, row houses, summer cottages, enclosed terraces, grill cottages, saunas, industrial applications, restaurants, public spaces
|
Suitable fuels
|
Wood, pellets, gas, oil
|
Fire safety distance (mm)
|
110mm (penetrations: 80mm when additional insulation is max 200mm high)
|
Thermal insulation value
|
0,72m2K/W – at reference temperature 200 °C
|
Structure from inside out
|
Inner pipe, mineral wool (Paroc Fire Section), steel jacket
|
Flue pipe sizes (mm) |
150, 175, 200, 250, 300 |
Outer diameters (mm) |
238, 265, 290, 340, 390
|
Temperature class
|
T600
|
Wall penetrations
|
Yes
|
For enclosed structures
|
Yes
|
Lateral shifts
|
Yes
|
Product standard
|
EN 1856-1:2009
|
Type code
|
T600-N1-D/W-Vm-L50060-G110 / T600-N1-D/W-Vm-L20070-G110
|